Samsung - Samsung WindFree™ Max Heat® RXX12ACD Heat Pump Split System, 208-230 V, 10 A, 12000 Btu/hr Cooling, 1 ph-Phase, Steel

  • Item #: RXX12ACD
  • Manufacturer: RXX12ACD
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Samsung WindFree™ Max Heat® Heat Pump Split System, 208-230 V, 10 A, 27 W, 60 Hz, 1 ph Phase, 3 Fan Speeds, 12000 Btu/hr Heating, 12000 Btu/hr Cooling, 463 cfm Heating CFM Rating, 427 cfm Cooling CFM Rating, 14.1 EER Rating, 24 SEER, Flared Connection, DC Inverter Twin Rotary Compressor, R-32 Refrigerant, 46 dBA Heating Sound Level, 46 dBA Cooling Sound Level, Wall Mounting, Steel, Finish: Galvanized/Powder-Coated, -22 to 75 deg F Heating Operating Temperature, 0 to 115 deg F Cooling Operating Temperature, 11-1/4 in Overall Length, 31-1/8 in Overall Width, 21-9/16 in Overall Height

  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_RXX12ACD_Submittal.pdf
  • The system shall provide 100% heating capacity at -4°F outdoor temperature and high heating capacity at -22°F outdoor temperature
  • The outdoor unit shall have a base pan heater as standard for optimal defrost cycle water drainage
  • The indoor unit shall feature WindFree™* mode
  • When activated in cooling mode the unit will close its louver and will disperse air into the space through thousands of micro-holes on the front of the indoor unit preventing cold air drafts on occupants
  • The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
  • The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable
  • Indoor unit chassis shall be UL94 V0 with a galvanized steel mounting bracket
  • The indoor unit shall have easy access to wire, pipe, and drain connections via the access panel on the bottom of the unit for simple installation and service
  • The outdoor unit shall be galvanized steel with a baked-on powder coated finish for durability
  • The heat exchangers shall be mechanically bonded fin to copper tube
  • The system shall utilize low-GWP R-32 refrigerant
  • The compressor shall be hermetically sealed, inverter controlled, BLDC Rotary
  • Refrigerant flow shall be controlled by an electronic expansion valve at the outdoor unit
  • The indoor fan shall be a single cross-flow type
  • Three fan speed settings and auto settings
  • Automatic (motorized) vertical swing (up/down) and horizontal swing (left/right) louvers