Samsung - Samsung WindFree™ Standard RXX09AMD Heat Pump Split System, 208-230 V, 10 A, 9000 Btu/hr Cooling, 1 ph-Phase, Steel

  • Item #: RXX09AMD
  • Manufacturer: RXX09AMD
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading
Product Image Description Quantity Price Availability
NoImage NoImage Non-flared Lineset, wireless, 1/4" liquid line x 3/8" suction line, 30 ft L, 1/2" insulation copper

Item #: LS-1/4X3/8-30

loading loading

Samsung WindFree™ Standard Heat Pump Split System, 208-230 V, 10 A, 27 W, 60 Hz, 1 ph Phase, 3 Fan Speeds, 11000 Btu/hr Heating, 9000 Btu/hr Cooling, 396 cfm Heating CFM Rating, 364 cfm Cooling CFM Rating, 15 EER Rating, 25 SEER, DC Inverter Twin Rotary Compressor, R-32 Refrigerant, 45 dBA Heating Sound Level, 45 dBA Cooling Sound Level, Wall Mounting, Steel, Finish: Galvanized/Powder-Coated, -5 to 75 deg F Heating Operating Temperature, 14 to 115 deg F Cooling Operating Temperature, 11-1/4 in Overall Length, 31-1/8 in Overall Width, 21-9/16 in Overall Height

  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_RXX18AMD_Instruction_Installation_Manual.pdf
  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_RXX09AMD_Submittal.pdf
  • The indoor unit shall feature WindFree™* mode
  • When activated in cooling mode the unit will close its louver and will disperse air into the space through thousands of micro-holes on the front of the indoor unit preventing cold air drafts on occupants
  • The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
  • The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable
  • Indoor unit chassis shall be UL94 V0 with a galvanized steel mounting bracket
  • The indoor unit shall have easy access to wire, pipe, and drain connections via the access panel on the bottom of the unit for simple installation and service
  • The outdoor unit shall be galvanized steel with a baked-on powder coated finish for durability
  • The heat exchangers shall be mechanically bonded fin to copper tube Refrigerant System
  • The system shall utilize low-GWP R-32 refrigerant
  • The compressor shall be hermetically sealed, inverter controlled, BLDC Rotary
  • Refrigerant flow shall be controlled by an electronic expansion valve at the outdoor unit
  • The indoor fan shall be a single cross-flow type
  • Three fan speed settings and auto settings
  • Automatic (motorized) vertical swing (up/down) and horizontal swing (left/right) louvers