Samsung - Samsung MIM-B14U External Contact Control Module, 3-1/8 in L, 2 in W, 5 V Input, 220 V Control

  • Item #: MIM-B14U
  • Manufacturer: MIM-B14U
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

External contact control module to control an indoor unit (on-off) via 0 V dry contact. MIM-B14 also provides an operation and error out put (0 V dry contact) signal. MIM-B14 is also used for various other indoor unit operation depending on indoor unit series and model (DVM S supplemental heat control and unoccupied room control). MIM-B14 can also install in DVM S outdoor units to monitor system on-off status, error status and to manually enable night time quiet operation mode.

Samsung External Contact Control Module, 3-1/8 in Length, 2 in Width, 5 V Input, 220 V, 3 A, Additional Information: 5 mA Operation Signal Input

  • Direct indoor unit on-off control (a single evaporator) by external contact, 0 V signal (indoor unit control will vary based on indoor unit model and series, consult indoor unit installation manuals and supporting documents for full operation details)
  • Outdoor unit night time quiet mode manual activation by external contact, 0 V signal (when installed in supported MAIN DVM S/DVM S2 outdoor units)
  • Indoor unit control with simple contact input
  • Indoor unit operation and error state output through relay contact
  • Outdoor unit compressor operation and error state and manual activation of night quiet mode (when installed in supported DVM S/DVM S2 outdoor units)
  • Installs inside individual indoor units that need control or in main outdoor unit (DVM S/DVM S2 Series outdoor units only)
  • Control indoor unit and have synchronous control with other devices through the external contact input/output signals
  • Operation output relay can be configured to open/close based on operation on-off or thermal on-off state (compressor on-off state when installed in outdoor unit)
  • Backup unit control when using the emergency temperature output (ETO) option settings for supported DVM S and CAC indoor units, (1) MIM-B14 per indoor unit required
  • DVM S indoor unit supplemental heat control with configurable temperature offset and time delay settings