Samsung - Samsung Max Heat® FJM Series AJ030CXS4CH/AA Heat Pump Condensing Unit, 208/230 V, 8.9/10 A, 28400 Btu/hr Cooling, Steel

  • Item #: JXH30S4C
  • Manufacturer: AJ030CXS4CH/AA
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Samsung Max Heat® Heat Pump Condensing Unit, Series: FJM Series, 208/230 V, 8.9/10 A, 60 Hz, 1 ph Phase, 28600 Btu/hr Heating, 28400 Btu/hr Cooling, 3320 cfm Heating CFM Rating, 13.5 EER Rating, 22.5 SEER, 10.4 HSPF, Inverter Twin BLDC Rotary Compressor, R-410A Refrigerant, 1/4 in Liquid Line, 3/8 in, 1/2 in Suction Line, 55 dBA Heating Sound Level, 52 dBA Cooling Sound Level, Steel, Finish: Galvanized/Powder-Coated, -13 to 75 deg F Heating Operating Temperature, 14 to 114.8 deg F Cooling Operating Temperature, 13 in Overall Length, 37 in Overall Width, 47-5/8 in Overall Height, Additional Information: 4-Port

  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AJ030CXS4CH_AA_Instruction_Installation_Manual.pdf
  • pdfService Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AJ020BXJ2CH_Service_Manual.pdf
  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AJ030CXS4CH_AA_Submittal.pdf
  • The Samsung Max Heat® system shall provide high heating capacity at -13 deg F (-25 deg C) outside temperature
  • The outdoor unit shall supply power individually to the indoor units via 14 AWG X 3 power wire
  • The outdoor unit shall have a base pan heater as standard to ensure optimal defrost cycle water drainage
  • Auto-restart after power loss
  • Available maximum current setting option to reduce operating current
  • System energy consumption can be viewed using Samsung SmartThings mobile app (not revenue grade, for reference only)
  • Soft-start to reduce current demand during compressor start
  • Auto or manual addressing of indoor units
  • The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability
  • The heat exchanger shall be mechanically bonded fin to copper tube
  • Control signal shall be a DDC type signal
  • Interconnect control wire between outdoor and indoor units shall be 16AWG X 2
  • Controls shall integrate with a BMS system
  • The system shall integrate with the Samsung Controls solution
  • The refrigerant shall be R410A
  • The compressor shall be hermetically sealed, inverter controlled, Twin BLDC Rotary
  • Refrigerant flow shall be controlled by 4 separate electronic expansion valves at outdoor unit