Samsung - Samsung AJ012DNZDCG/AA Multi-Position Air Handler, 12000 Btu/hr BTU, 244 to 374 cfm, 208-230 V, 1.5 A, 3.52 kW, 60 Hz

  • Item #: AJ012DNZDCG
  • Manufacturer: AJ012DNZDCG/AA
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Samsung Multi-Position Air Handler, 1 ton Nominal Capacity, 12000 Btu/hr Cooling Capacity, 13500 Btu/hr Heating, 12000 Btu/hr, 208-230 V, 1.5 A, 3.52 kW Wattage, 60 Hz, 1 ph, 244 to 374 cfm, Flared Connection, R-32 Refrigerant, 36 dBA Sound Level, 3/4 in Connection, 1/4 in Liquid Line, 3/8 in Suction Line, 3 Speed, Constant Torque Motor, 0.4 in-WC, Steel, Galvanized, 64 to 90 deg F Cooling, <=86 deg F Heating, 43 in H x 17-1/2 in W x 21 in D, For Use With Multi-Zone Systems

  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AJ012DNZDCG_AA_Instruction_Installation_Manual.pdf
  • pdfOwners/User Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AJ012DNZDCG_AA_Owners_User_Manual.pdf
  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AJ012DNZDCG_AA_Submittal.pdf
  • The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
  • The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire (when accessory electric heat kits are not installed)
  • Insulated, galvanized steel
  • The heat exchanger shall be mechanically bonded aluminum fin to copper tube
  • Refrigerant flow shall be controlled by electronic an expansion valve at the outdoor unit
  • The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection (MIM-B14U accessory is required)
  • Three fan speeds and auto setting
  • Control wiring shall be 2 X 16 AWG wire
  • The unit shall be operated via a wireless or wired remote control with DDC type signal
  • Dual set temperature support when connected to supported controllers
  • Wired or wireless controllers must be purchased separately
  • External heat control functionality allows for configuration of fan operation during auxiliary heat operation, defrost, and emergency heat (MIM-B14U accessory required when controlling heating devices other than VHK-***C electric heat kits)
  • External heat control configuration settings include outside ambient external heat lockout, outside ambient compressor lockout, and time delay options (MIM-B14U accessory required when controlling heating devices other than VHK-***C electric heat kits)
  • Emergency heat functionality allows the system to continue controlling the external heat source even when system errors prevent the heat pump from operating (MIM-B14U accessory required when controlling heating devices other than VHK-***C electric heat kits)
  • External heat control functionality allows for configuration of fan operation during auxiliary heat operation, defrost, and emergency heat
  • Emergency heat functionality allows the system to continue controlling the external heat source even when system errors prevent the heat pump from operating
  • Emergency Temperature Output (ETO) function: when indoor unit is in error status or when room temperature exceeds configurable temperature level, the system outputs a signal to an external source, e.g., backup system, building management system, alert device (ex: status light, warning lamp, buzzer)