Samsung - Samsung WindFree™ CXH24ADB AC024BXADCH Heat Pump Split System Outdoor Unit, 208 - 230 V, 24000 Btu/hr Cooling, Steel

  • Item #: AC024BXADCH
  • Manufacturer: AC024BXADCH
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Outdoor unit for CAC Slim Duct, Duct S, WindFree™* 4-Way Cassette, WindFree™* Mini 4-Way Cassette, WindFree™* 1-Way Cassette, 360 Cassette, Multi-Position Air Handler, Console, and High-Wall units. For submittals, service manuals, and technical data books, refer to the respective indoor unit section.

Samsung WindFree™ Heat Pump Split System Outdoor Unit, Model: CXH24ADB, 208 - 230 V, 2.5/10.6/12.9 A Cooling, 2/12.4/23.5 A Heating, 125 W, 60 Hz, 1 ph Phase, 3 Fan Speeds, 27000 Btu/hr Heating, 24000 Btu/hr Cooling, 2684 cfm Condenser, 466 to 629 cfm Evaporator Heating CFM Rating, 10.3 EER Rating, 18.9 SEER, 10.8 HSPF, Flared Connection, Twin BLDC Rotary Compressor, R-410A Refrigerant, 1/4 in Liquid Line, 5/8 in Suction Line, 30 A Fuse Rating, Inverter Drive, 52 dBA Heating Sound Level, 50 dBA Cooling Sound Level, Steel, Finish: Galvanized/Powder-Coated, -13 to 75 deg F Heating Operating Temperature, 23 to 122 deg F Cooling Operating Temperature, 39-5/16 in Overall Length, 37 in Overall Width, 13 in Overall Height, Additional Information: CAC Classification, 2022 Version, AR9500 Wall-Mounted Design, Deluxe Feature

  • Tonnage 2 Ton
  • pdfFull Engineering Drawing https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC012BXADCH_Full_Engineering_Drawing.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC012BXADCH_Instruction_Installation_Manual.pdf
  • pdfService Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018BNHDCH_Service_Manual.pdf
  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC024BXADCH_Submittal.pdf
  • The indoor unit shall feature "WindFree™" mode*. In cooling mode, as room temperature nears set temperature, the unit will close its louver and will disperse air into the space through thousands of micro-holes on the front of the indoor unit preventing cold air drafts on occupants
  • The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
  • High-voltage terminal block temperature sensor to disable unit in the event of power connection overheating
  • Auto-restart after power loss
  • Soft-start compressor minimizing current inrush
  • Base pan heater equipped as standard
  • All heat exchangers shall be mechanically bonded aluminum fin to copper tube
  • The condensing unit heat exchanger salt spray test method: ISO-9227 - the heat exchanger showed no unusual rust or corrosion development to 3,000 hours
  • The system shall provide 100% heating capacity at -4 degF (-20 degC)