Samsung - Samsung AC018DXSCCF/AA Single Zone Mini-Split Air Conditioner Condenser, 208-230 V, 9.7 A, 18000 Btu/hr Cooling, Steel

  • Item #: AC018DXSCCF
  • Manufacturer: AC018DXSCCF/AA
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Samsung Single Zone Mini-Split Air Conditioner Condenser, 208-230 V, 9.7 A, 5.2 kW, 60 Hz, 1 ph, 18000 Btu/hr Cooling, 593 to 841 cfm Cooling CFM Rating, 12 EER Rating, 18.6 SEER, Flared Connection, 1/4 in Liquid Line, 1/2 in Suction Line, 15 A Fuse Rating, Inverter Drive, Tonnage: 1-1/2 ton, 58 dBA Cooling Sound Level, Steel, Galvanized, 23 to 122 deg F Cooling Operating Temperature, 34-5/8 in Overall Length, 25-1/8 in Overall Width, 12-3/16 in Overall Height, Brushless DC Motor, R-32 Refrigerant Type, Twin Rotary Compressor Type

  • Liquid Line Size 1/4 in
  • Tonnage 1-1/2 ton
  • Voltage Rating 208-230 V
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018DXSCCF_AA_Catalog.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018DXSCCF_AA_Instruction_Installation_Manual.pdf
  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018DXSCCF_AA_Submittal.pdf
  • Low ambient cooling down to -40 deg F
  • The system shall feature comfort humidity control. Utilizing an integral humidity sensor, the system optimizes the indoor unit coil temperature according to the dew point, maximizing energy savings while still providing space dehumidification and occupant comfort
  • The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
  • Auto-restart after power loss
  • Soft-start compressor minimizing current inrush
  • The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable
  • Outdoor unit: Galvanized steel with a baked-on powder coated finish for durability
  • All heat exchangers shall be mechanically bonded aluminum fin to copper tube
  • The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
  • The system shall utilize low-GWP R-32 refrigerant
  • Refrigerant flow shall be controlled by electronic an expansion valve at the outdoor unit
  • The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection when the optional refrigerant leak detector is installed and configured (leak detector and MIM-B14U accessories are required)
  • Smart pressure control feature that adjusts fan speed based on ESP delivering consistent heating and cooling power
  • The indoor unit shall have automatic air volume scanning for simple setup and optimized comfort settings for the occupant
  • Control wiring shall be 2 X 16 AWG wire
  • No additional interface modules/adapters are required when connecting to Samsung central control options
  • The unit shall be operated via a wireless or wired remote control with DDC type signal
  • Wired or wireless controllers must be purchased separately
  • The outdoor unit shall have snow accumulation prevention option setting to prevent snow drifting against an idle outdoor unit
  • Night-time Quiet Mode: reduction of operational sound during evening hours (automatic or manual activation)