Samsung - Samsung WindFree™ CNG18NDD Mini 4-Way Multi-Split Indoor Unit, 208-230 V, 0.3 A, 18000 Btu/hr BTU, 1 ph-Phase

  • Item #: AC018DNNDCG
  • Manufacturer: CNG18NDD
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Samsung WindFree™ Mini 4-Way Multi-Split Indoor Unit, 208-230 V, 0.3 A, 30 W, 60 Hz, 1 ph Phase, 3 Fan Speeds, 18000 Btu/hr, 371 cfm, Flared Connection, R-32 Refrigerant, Tonnage: 1.42 ton, 39 dBA Sound Level, Polypropylene, 64 to 90 deg F, 22-5/8 in Overall Length, 22-5/8 in Overall Width, 9-13/16 in Overall Height, For Use With: FJM Multi-Zone Systems

  • Sound Level 39 dBA
  • Tonnage 1.42 ton
  • Voltage Rating 208-230 V
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNG09JDD_Catalog.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNG09JDD_Instruction_Installation_Manual.pdf
  • pdfOwners/User Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNG09JDD_Owners_User_Manual.pdf
  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNG18NDD_Submittal.pdf
  • The indoor unit shall feature WindFree™* mode, When activated in cooling mode the unit will close its louver and will disperse air into the space through thousands of micro-holes on the front of the indoor unit, preventing cold air drafts on occupants
  • The indoor unit shall have an integral condensate pump with maximum 29" lift from bottom of the unit with check valve and float switch to disable unit in the event of condensate overflow
  • The indoor unit fascia panel shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
  • The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable
  • Insulated, HIPS chassis and fascia panel certified to UL94 V0
  • The indoor unit shall include a knock-out for outside air capability (booster fan connection)
  • The heat exchanger shall be mechanically boded aluminum fin to copper tube
  • Refrigerant flow shall be controlled by an electronic expansion valve at the outdoor unit
  • The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection when the indoor unit refrigerant leak detector detects a refrigerant leak (MIM-B14U accessory is required)
  • Three fan speed settings and auto settings
  • Washable filter as standard
  • Fascia panel shall have LED display, infrared receiver, and motorized louvers
  • The WindFree™* function will close the supply air outlet louver while in cooling mode to gently disperse cool air into the space without blowing directly onto occupants
  • The WindFree™* feature is optional and can be enabled using central or local control options