Samsung - Samsung CNG12LDD Slim Duct Multi-Split Indoor Unit, 208-230 V, 1.06 A, 12000 Btu/hr BTU, 1 ph-Phase, Steel

  • Item #: AC012DNLDCG
  • Manufacturer: CNG12LDD
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Samsung Slim Duct Multi-Split Indoor Unit, 208-230 V, 1.06 A, 120 W, 60 Hz, 1 ph Phase, 3 Fan Speeds, 12000 Btu/hr, 456 cfm, Flared Connection, R-32 Refrigerant, Tonnage: 1 ton, 34 dBA Sound Level, Steel, 64 to 90 deg F, 17-5/16 in Overall Length, 35-7/16 in Overall Width, 7-13/16 in Overall Height, For Use With: FJM Multi-Zone Systems

  • Sound Level 34 dBA
  • Tonnage 1 ton
  • Voltage Rating 208-230 V
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNG09JDD_Catalog.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNG09LDD_Instruction_Installation_Manual.pdf
  • pdfOwners/User Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNG09LDD_Owners_User_Manual.pdf
  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_CNG12LDD_Submittal.pdf
  • The system shall provide high heating capacity at -4°F (-20°C) with heating operation down to -13°F (-25°C)
  • The outdoor unit shall have a base pan heater as standard for optimal defrost cycle water drainage
  • The indoor unit shall have an integral condensate pump with maximum 29” lift from bottom of the unit with check valve and float switch that disables indoor in the event of condensate overflow
  • The system shall feature comfort humidity control. Utilizing an integral humidity sensor, the system optimizes the indoor unit coil temperature according to the dew point, maximizing energy savings while still providing space dehumidification and occupant comfort
  • The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
  • Auto-restart after power loss
  • Soft-start compressor minimizing current inrush
  • The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable
  • Outdoor unit shall be galvanized steel with a baked-on powder coated finish for durability
  • Indoor unit: Insulated, galvanized steel
  • All heat exchangers shall be mechanically bonded aluminum fin to copper tube
  • The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
  • The system shall utilize low-GWP R-32 refrigerant
  • Refrigerant flow shall be controlled by electronic an expansion valve at the outdoor unit
  • The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection when the optional refrigerant leak detector is installed and configured (leak detector and MIM-B14U accessories are required)
  • Three fan speeds and auto setting