Samsung - Samsung AC012BXADCH Single-Zone Heat Pump Split System Outdoor Unit, 208 - 230 V, 12000 Btu/hr Cooling, 1 ph -Phase

  • Item #: AC012BXADCH
  • Manufacturer: AC012BXADCH
  • Brand Name: Samsung
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Outdoor unit for CAC Slim Duct, Duct S, WindFree™* 4-Way Cassette, WindFree™* Mini 4-Way Cassette, WindFree™* 1-Way Cassette, 360 Cassette, Multi-Position Air Handler, Console, and High-Wall units. For submittals, service manuals, and technical data books, refer to the respective indoor unit section.

Samsung Single-Zone Heat Pump Split System Outdoor Unit, 208 - 230 V, 1.3/4.7/5.9 A Cooling, 1.1/5.1/9.3 A Heating, 40 W Condenser, 84 W Evaporator, 60 Hz, 1 ph Phase, 3 Fan Speeds, 14000 Btu/hr Heating, 12000 Btu/hr Cooling, 1060 cfm Condenser, 300 to 399 cfm Evaporator Heating CFM Rating, 12 EER Rating, 20.7 SEER, 10.8 HSPF, Flared Connection, BLDC Rotary Compressor, R-410A Refrigerant, 1/4 in Liquid Line, 3/8 in Suction Line, 15 A Fuse Rating, Inverter Drive, 48 dBA Heating Sound Level, 47 dBA Cooling Sound Level, Steel, Finish: Galvanized/Powder-Coated, 4 to 75 deg F Heating Operating Temperature, 23 to 122 deg F Cooling Operating Temperature, 11-1/4 in Overall Length, 31-1/8 in Overall Width, 21-9/16 in Overall Height, Additional Information: CAC Classification, 2022 Version, AR9500 Wall-Mounted Design, Deluxe Feature

  • Tonnage 1 Ton
  • pdfSubmittal - AC012BXADCH https://www.shearersupply.com//ASSETS/DOCUMENTS/ITEMS/EN/AC012BNLDCH+(CNH12LDB)_Submittal_CAC+Single+Zone_Slim+Duct_01132022.pdf
  • pdfFull Engineering Drawing https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC012BXADCH_Full_Engineering_Drawing.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC012BXADCH_Instruction_Installation_Manual.pdf
  • pdfService Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018BNHDCH_Service_Manual.pdf
  • pdfSubmittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC012BXADCH_Submittal.pdf
  • The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
  • High-voltage terminal block temperature sensor to disable unit in the event of power connection overheating
  • Auto-restart after power loss
  • Soft-start compressor minimizing current inrush
  • All heat exchangers shall be mechanically bonded aluminum fin to copper tube
  • The condensing unit heat exchanger salt spray test method: ISO-9227- the heat exchanger showed no unusual rust or corrosion development to 3,000 hours