resideo - resideo S8610U3009/U Universal Intermittent Pilot Ignition Module, 24 VAC

  • Item #: S8610U3009
  • Manufacturer: S8610U3009/U
  • Brand Name: resideo
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Pilot Ignition Modules and Kits from reside are designed to provide easy field replacement of a wide range of OEM intermittent pilot ignition modules. The S8610U Module provides ignition sequence, flame-monitoring and safety shutoff for intermittent pilot central furnaces, residential boilers and other heating appliances.

resideo Universal Intermittent Pilot Ignition Module, Series: S8610 Series, 24 VAC, Liquid Propane, Natural Gas Gas, 15 or 90 s Igniter Warm-Up Time, 30 s Pre Purge Time, Continuous Retries, 5-7/16 in Width, 2-5/8 in Depth, 3-15/16 in Height, Additional Information: -40 to 165 deg F Ambient Temperature

  • Series S8610 Series
  • Voltage Rating 24 VAC
  • Gas Type Liquid Propane, Natural Gas
  • Igniter Warm-Up Time 15 or 90 s
  • Width 5-7/16 in
  • Depth 2-5/8 in
  • Height 3-15/16 in
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Honeywell_S8610U3009_Catalog.pdf
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/resideo_S8610U3009U_Catalog.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/resideo_S8610U3009U_Instruction_Installation_Manual.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/resideo_S8610U3009U_Specification_Sheet.pdf
  • Replaces over 400 White-Rogers, Robertshaw and Resideo intermittent pilot ignition modules
  • Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances
  • Provides 100% pilot gas shutoff if pilot fails to light - after 6 min delay, trial for ignition is repeated, ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed
  • For use with Natural or LP gas
  • Includes spark cable adapters to allow field replacement of both Resideo and competitive controls without replacing existing spark cable