Fluke® - FLUKE ELECTRONICS, 116, 600 V, 1000 nF to 9999 µF 9V Alkaline Battery

  • Item #: 116
  • Manufacturer: Fluke 116
  • Brand Name: Fluke®
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading
loading

Compact true-rms meter for HVAC (heating ventilation air conditioning) troubleshooting. The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors

  • Type HVAC Multimeter
  • Measuring Range 600 mV (DC Millivolts & AC Millivolts);6 to 600 V (DC & AC Volts);600 V (Auto Volts);600 ¿ (Continuity);600 ¿ to 6 M¿ (Resistance);2 V (Diode Test);1000 nF to 9999 µF (Capacitance);1 nF to 500 µF (LoZ Capacitance);-40 to 752 deg F (Temperature²);600.0 µA (AC & DC µamps);99.99 Hz, to 9.999 Hz, 50 Hz (Frequency)
  • Resistance 600.0 O;6.000 kO;60.00 kO;600.0 kO;6.000 MO;40.00 MO
  • Voltage Rating 600
  • Temperature Rating -40 to +752
  • Display Digital
  • Safety Rating Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
  • Capacitance 1,000 nF to 9,999 µF
  • Accuracy ±0.5 (DC Millivolts & DC Volts);2, 4 (Auto Volts);1, 2 (AC Millivolts & AC Volts);<20 ¿ (Beeper On), > 250 ¿ (Off) (Continuity);0.9, 1.5 (Resistance);0.9 (Diode Test);1.9, 5 (Capacitance);10 (LoZ Capacitance);1 (Temperature²);1 (AC & DC µamps & Frequency)
  • Battery Type 9V Alkaline
  • Resolution 0.1 mV (DC Millivolts & AC Millivolts);0.001 to 0.1 V (DC & AC Volts);0.1 V (Auto Volts);1 ¿ (Continuity);0.1 ¿ to 0.001 M¿ (Resistance);0.001 V (Diode Test);1nF to 1 µF (Capacitance);0.2 deg F (Temperature²);0.1 µA (AC & DC µamps);0.01 Hz to 0.01 kHz (Frequency)
  • Color Yellow/Gray
  • pdfTechnical Data Sheet https://www.shearersupply.com//ASSETS/DOCUMENTS/ITEMS/EN/Fluke_116_1_Technical_Data_Sheet.pdf
  • pdfUser Manual https://www.shearersupply.com//ASSETS/DOCUMENTS/ITEMS/EN/Fluke_116_User_Manual.pdf
  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance:helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated

Standard/Approvals: Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for Measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1;UL;CE;CSA;TÜV;(N10140);VDE