Samsung AM012JNZDCH - Samsung, DVM S, AM012JNZDCH, Multi-Position Air Handler Unit, 12000 Btu/hr Cooling

  • Item #: AM012JNZDCH
  • MFR: AM012JNZDCH
  • loading

Samsung Multi-Position Air Handler Unit, Series: DVM S, 12000 Btu/hr Cooling, 208 to 230 VAC 60 Hz 1 ph, 43 in W x 17-1/2 in H x 21 in D

Color      :      Gray
Control Type      :      Electronic Expansion Valve
Cooling Capacity      :      12,000 Btu/hr
Dimensions      :      43 in W x 17-1/2 in H x 21 in D
Discharge Line Size      :      1/4
Flow Rate      :      373
Frequency Rating      :      60 Hz
Heating Capacity      :      13,500 Btu/hr
Material      :      Galvanized Steel
Motor Rating      :      290
Motor Type      :      Constant-Torque
Mounting Type      :      Floor Stand
Nominal Capacity      :      12,000 Btu/hr (Cooling);13,500 Btu/hr (Heating)
Number of Phase      :      1 Ph
Number of Speeds      :      2
Refrigerant Type      :      R-410A
Series      :      DVM S
Sound Level      :      38
Suction Line Size      :      1/2
Temperature Rating      :      86 deg F
Tonnage      :      1 Ton
Type      :      Multi-Position
Voltage Rating      :      208 to 230 VAC
  • Compatible with Samsung DVM S, DVM S Water, and DVM Eco systems (AM*********/AA).
  • High-voltage terminal block temperature sensor to disable unit in the event overheating of controls power connection.
  • Multiposition - vertical, horizontal left, and horizontal right.
  • Construction: The unit shall be constructed of insulated, powder coated, galvanized steel
  • Heat Exchanger: The heat exchanger shall be mechanically bonded fin to copper tube
  • Indoor Fan: Indoor fan is a double-inlet, forward curve, centrifugal type with a single constant-torque (ECM) fan motor. Two operating fan speeds (standard/reduced). Five fan speed taps for optional air flow setting during Installation. The indoor unit shall have the capability to turn the fan off in heating or cooling modes while in thermal-OFF status (external sensor required).
  • Controls: Simple external contact control contacts included as standard for 0 volt ON/OFF control (ex: auxiliary drain switch). The indoor unit shall integrate with the Samsung NASA Controls Network Solution. The indoor unit PCB shall have an integral infrared receiver to allow simple programming with a wireless controller. The indoor unit shall have an error output signal relay (ERROR= open, NO ERROR = closed). Controls shall integrate with a BMS system. Control wiring shall be 2 X 16 AWG shielded wire.
  • Air Filtration: The unit does not include an air filter as standard.

Standard/Approvals: ETL Listed

Application: Residential

  • pdfInstallation Manual https://www.shearersupply.com//ASSETS/DOCUMENTS/ITEMS/EN/Samsung_AM012JNZDCH_Installation_Manual.pdf
  • pdfSubmittal Sheet https://www.shearersupply.com//ASSETS/DOCUMENTS/ITEMS/EN/Samsung_AM012JNZDCH_Submittal_Sheet.pdf
  • pdfTechnical Sheet https://www.shearersupply.com//ASSETS/DOCUMENTS/ITEMS/EN/Samsung_AM018JNZDCH_AA_Technical_Sheet.pdf